摘要 :
Background. Human metapneumovirus (hMPV) commonly causes upper and lower respiratory tract infections. Here, we performed long-term retrospective surveillance of hMPV infection among patients hospitalized in South Korea between 20...
展开
Background. Human metapneumovirus (hMPV) commonly causes upper and lower respiratory tract infections. Here, we performed long-term retrospective surveillance of hMPV infection among patients hospitalized in South Korea between 2007 and 2016 and investigated seasonal dynamics and clinical characteristics associated with each virus subtype/genotype.
收起
摘要 :
The prevalence of Tropheryma whipplei varies depending on age, region, and underlying disease. We estimated the prevalence of T. whipplei in the stools of Korean patients with diarrhea using real-time PCR (RT-PCR) and compared thr...
展开
The prevalence of Tropheryma whipplei varies depending on age, region, and underlying disease. We estimated the prevalence of T. whipplei in the stools of Korean patients with diarrhea using real-time PCR (RT-PCR) and compared three RT-PCR targets, rpoB, hsp65, and Dig15. A total of 1404 nucleic acid samples extracted from the stools of Korean patients with diarrhea were tested using an initial RT-PCR targeting T. whipplei-specific regions of 16S–23S rRNA intergenic spacer. Subsequently, the samples positive for the initial RT-PCR were tested using the follow-up RT-PCRs targeting rpoB, hsp65, and Dig15 and analyzed by sequencing to confirm the presence of T. whipplei. We estimated the prevalence of T. whipplei and compared them according to gender and age. We also compared the performance of three targets in the follow-up RT-PCRs. T. whipplei was detected in 1.4% of all samples (20 of 1404), and there were no differences according to gender and age. In pediatric samples (≤?19?years), T. whipplei was detected higher in children aged 6–19 than in those aged 1–5 (2.7% vs. 0.7%, P?=?0.01). Sensitivities of the rpoB, hsp65, and Dig15 RT-PCR were 50.0%, 85.0%, and 95.0%, respectively; specificities were 100.0%, 100.0%, and 84.6%, respectively. This is the first study that estimated the prevalence of T. whipplei in the stools of Korean patients with diarrhea. This study demonstrated the presence of T. whipplei in stools of Koreans, even though the bacterium was detected low. The RT-PCRs targeting hsp65 and Dig15 showed reliable performance, and a multiplex PCR including these targets is expected to be useful for T. whipplei detection.
收起
摘要 :
Inconclusive results in SARS-CoV-2 molecular assays cause confusion among clinicians and delay appropriate infection prevention and control. In this study, we aimed to characterize the respiratory specimens associated with inconcl...
展开
Inconclusive results in SARS-CoV-2 molecular assays cause confusion among clinicians and delay appropriate infection prevention and control. In this study, we aimed to characterize the respiratory specimens associated with inconclusive SARS-CoV-2 molecular assay results. We re-evaluated inconclusive specimens by 3 additional RT-PCR assays and attempted to detect subgenomic RNA (sgRNA) in these specimens. Among follow-up tests from confirmed SARS-CoV-2 cases, 36.3% of the inconclusive results were classified as presumptive positive results (45/124). However, none of the specimens from 36 screening cases was classified as a presumptive positive result. Among 160 inconclusive specimens, sgRNAs were detected in 78 samples (48.8%): 58 were confirmed cases (58/124, 46.8%) and 20 were screening cases (20/36, 55.6%). The results of our study suggest the recommendation of considering inconclusive results as positive results for confirmed SARS-CoV-2 cases. In screening cases, viral remnants could be partially amplified in PCR assays, and these inconclusive results could be related to previous infections. In addition, sgRNAs were detected in about half of the inconclusive specimens; however, the clinical significance of sgRNA is not yet clear.
收起
摘要 :
Objectives We evaluated performance and measurement uncertainty of the newly released ARCHITECT 25-OH vitamin D 5P02 assay (Abbott Diagnostics, Abbott Park, IL).
摘要 :
Our aim was to determine the detection rate of respiratory viruses (RVs) in feces of patients with acute viral respiratory infection (AVRI) and the detection rate of diarrheal viruses (DVs) in nasopharyngeal samples from patients ...
展开
Our aim was to determine the detection rate of respiratory viruses (RVs) in feces of patients with acute viral respiratory infection (AVRI) and the detection rate of diarrheal viruses (DVs) in nasopharyngeal samples from patients with acute viral gastroenteritis. The relationships between the presence of fecal RVs or nasopharyngeal DVs and their impacts on the clinical severity were also investigated. A total of 144 fecal specimens were collected from AVRI patients and 95 nasopharyngeal specimens were collected from acute viral gastroenteritis patients. Clinical characteristics and laboratory profiles were compared between subgroups on the basis of the presence or absence of virus in the specimens. The detection rate of RVs in feces was 17.4% (25/144), whereas the detection rate for viruses identical to the respiratory pathogen was 10.4% (identical group, 15/144). Within the identical group, adenovirus (86.7%, 13/15) was most commonly found. Patients in the identical group showed statistically higher values for C-reactive protein, mean age, increased frequency of vomiting, and decreased frequency of chest film involvement and cough (p < 0.05). The detection rate of nasopharyngeal DVs among acute viral gastroenteritis patients was 19.0% (18/95), and in the identical group it was 15.8% (15/95). Norovirus group II and enteric adenovirus were the major pathogens detected in the identical group. There were no significant differences in clinical characteristics and laboratory profiles between the subgroups. In conclusion, the major pathogens of fecal RV and nasopharyngeal DV were adenovirus and norovirus group II, respectively. However, their relationship with the clinical symptoms or disease severity is unclear.
收起
摘要 :
Recently, several studies have revealed that commercial microbial identification systems do not accurately identify the uncommon causative species of candidiasis, including Candida famata, Meyerozyma guilliermondii, and C. auris. ...
展开
Recently, several studies have revealed that commercial microbial identification systems do not accurately identify the uncommon causative species of candidiasis, including Candida famata, Meyerozyma guilliermondii, and C. auris. We investigated the accuracy of species-level identification in a collection of clinical isolates previously identified as C. famata (N = 38), C. lusitaniae (N = 1 2), and M. guilliermondii (N = 5) by the Vitek 2 system. All 55 isolates were re-analyzed by the Phoenix system (Becton Dickinson Diagnostics), two matrix-assisted laser desorption ionization-time of flight mass spectrometry analyzers (a Vitek MS and a Bruker Biotyper), and by sequencing of internal transcribed spacer (ITS) regions or 26S rRNA gene D1/D2 domains. Among 38 isolates previously identified as C. famata by the Vitek 2 system, the majority (27/38 isolates, 71.1%) were identified as C. tropicalis (20 isolates) or C. albicans (7 isolates) by ITS sequencing, and none was identified as C. famata. Among 20 isolates that were identified as C. tropicalis, 17 (85%) were isolated from urine. The two isolates that were identified as C. auris by ITS sequencing originated from ear discharge. The Phoenix system did not accurately identify C. lusitaniae, C. krusei, or C. auris. The correct identification rate for 55 isolates was 92.7% (51/55 isolates) for the Vitek MS and 94.6% (52/55 isolates) for the Bruker Biotyper, as compared with results from ITS sequencing. These results suggest that C. famata is very rare in Korea, and that the possibility of misidentification should be noted when an uncommon Candida species is identified.
收起
摘要 :
Objectives: There are no generally accepted serum biomarkers for Alzheimer's disease (AD). We investigated the clinical usefulness of measuring the serum hepcidin levels and iron profile in patients with AD.
摘要 :
The international normalized ratio (INR) may not be directly applicable to patients with liver disease. We aimed to establish an alternative INR calibration system for patients with liver disease and to evaluate the effect of thei...
展开
The international normalized ratio (INR) may not be directly applicable to patients with liver disease. We aimed to establish an alternative INR calibration system for patients with liver disease and to evaluate the effect of their use in chronic liver disease patients. Eighty-two patients with liver cirrhosis (LC) were included, and their prothrombin times (PTs) were measured by using 5 commercial thromboplastins. Each of the thromboplastins was also assigned an international sensitivity index (ISIliver) by the plasmas from LC patients. INRvka, INRliver, model for end-stage liver disease (MELD)(vka), MELDliver, Child-Pugh (Child)(vka), and Child(liver) scores were calculated. The coefficient of variance of INRvka was significantly larger than that of INRliver (P < 0.01). The mean difference in INRvka between the thromboplastins was also significantly larger than that in INRliver (P < 0.01). The total mean MELDliver score was higher than the total mean MELDvka score. The mean difference between the MELDvka and MELDliver scores (MELD score >= 15) was 3.2 %. We reconfirmed that the use of the alternative calibration system described herein for patients with liver disease may resolve the variability of INR measurement. Our data suggest that we would need to reevaluate the correlation between Child-Pugh class, MELD score, and clinical prognosis by using INRliver for patients with LC.
收起
摘要 :
Context.-In the XN series of hematology analyzers (Sysmex, Kobe, Japan), the probability of the presence of abnormal cells is indicated by flags based on Q values.
摘要 :
We estimated the measurement uncertainty (MU) of platelet concentration measured using the Sysmex XN system with two reference platelet counting methods described by DIN 58932-5 (PTB method) and the International Council for Stand...
展开
We estimated the measurement uncertainty (MU) of platelet concentration measured using the Sysmex XN system with two reference platelet counting methods described by DIN 58932-5 (PTB method) and the International Council for Standardization in Haematology (ICSH method). Ten blood samples were used to estimate and compare the MU of the XN system, and 30 samples were used to compare the methods. The standard uncertainty of the reference method was significantly higher for the ICSH method; the PTB method showed higher platelet concentrations than the ICSH method. When applying different methods with the XN system, optic counting showed higher MU compared to the other methods. There was good correlation among the two reference methods and three automated platelet-counting methods. We evaluated the MU in platelet concentrations measured using an automated hematology analyzer. Our results suggest that using the PTB method for calculating MU of the automated hematology analyzer is superior to the ICSH method because of its lower standard uncertainty.
收起